Vibration Mounts India

MFI-N5-M16x2.0x150

Model

Description

A spring isolator gives desired natural frequency to obtain phase difference in the frequencies for a rotating machine and impact generating machine. Viscous damping is an importatnt feature of an isolation sysytem. In most cases viscous damping is required to limit excessive movement which could occur as a machine operates at a speed near to, or coinciding with the resonant frequencies of the system. Generally this problem arises during slow run up and run down of rotating machines and during impact at each stroke in presses and hammers.

Technical Data

MODEL
MFI-N5-M16x2.0x150
Load (Kg)
2400-7200
HO mm
97
HI mm
112
Bolt Size
M16
Top Plate (AxB) (mm)
276X221
Bottom Plate (CxD) (mm)
271X256
CC (mm)
241
Natural Frequency (Hz)
3.5-11