Vibration Mounts India

Anti Vibration Table With Elastomeric Vibration Isolation, Series-DIT-E

Series:

Anti Vibration Table With Elastomeric Vibration Isolation With Granite Top, Series DIT-E-GN

Description:

Dynemech Anti Vibration Tables – Series DITE-GN are ideal for Testing / Quality Laboratories co-located with industrial units having high degree of vibration due to working machines like presses, hammers, VMCs etc. The Vibrations are isolated using Double-Layered Dp Elastomeric Sheets. These Anti-Vibration Tables have a Granite Surface Plate with Grade-00/Grade-1 accuracy for very precise measuring accuracies. We can select up-to five layers of insulation plate depending upon the vibrations present in the Testing Laboratory. These Vibration Tables provide the most economical solution where high frequency vibrations need to be removed. The passive vibrations from nearby motors and other heavy machinery is reduced by 65-70%. The vibration isolation efficiency of these tables can be further increased by placing more than 2 layers of our Dp insulation Sheets. Five layers of DP exhibits a natural frequency of 7-8 Hz. which damps most of the incoming frequencies above 20 Hz.

Applications:

The Vibration Isolated Table (VIT) finds usage in critical areas where reading accuracy of instruments like Balances, Galvanometers, Electronic Microscopes and Atomic Absorption Spectrophotometers, is affected by Vibrations.

Model Load (Kg) Length (mm) Width (mm)
DIT-E-GN-01 upto 400 500 500
DIT-E-GN-01-S1 upto 400 630 630
DIT-E-GN-02 upto 850 750 500
DIT-E-GN-03 upto-1250 900 600
DIT-E-GN-04 upto-1250 1000 800

Series:

Anti Vibration Table With Elastomeric Vibration Isolation With Honeycomb Breadboard, Series DIT-E-HC

Description:

Dynemech Anti Vibration Tables – Series DIT-E-HC are ideal for Testing / Quality Laboratories with having optical instruments. The Vibrations are isolated using Double-Layered Dp Elastomeric Sheets. These Anti-Vibration Tables have a Honeycomb table top. We can select up-to five layers of insulation plate depending upon the vibrations present in the Testing Laboratory.

Applications:

Used in optical industries, for mounting optical assemblies

Model Load (Kg) Length (mm) Width (mm)
DIT-E-HC-01-75759 upto 450 750 750
DIT-E-HC-02-90609 upto 500 900 600
DIT-E-HC-03-1008090 upto 600 1000 800
DIT-E-HC-04-12010090 upto 700 1200 1000
DIT-E-HC-05-15012090 upto 800 1500 1200
DIT-E-HC-06-18012090 upto 850 1800 1200
DIT-E-HC-07-24015090 upto 1000 2400 1500

Series:

Anti Vibration Table With Elastomeric Vibration Isolation With Corian Marble Top, Series DIT-E-CM

Description:

Dynemech Anti Vibration Tables – Series DIT-E-CM has a corian marble table top. High degree of vibration can be damped with the help of Dp Elastomeric sheets. We can select up-to five layers of insulation plate depending upon the vibrations present in the Testing Laboratory.

Applications:

The Vibration Isolated Table (VIT) finds usage in critical areas where reading accuracy of instruments like Balances, Galvanometers, Electronic Microscopes and Atomic Absorption Spectrophotometers, is affected by Vibrations

Model Load (Kg) Length (mm) Width (mm)
DIT-E-CM-01 upto 250 500 500
DIT-E-CM-02 upto 250 630 630
DIT-E-CM-03 upto 450 750 500
DIT-E-CM-04 upto-1250 900 600
DIT-E-CM-05 upto-1250 1000 800

Series:

Anti Vibration Table, Elastomeric Isolation With Wooden Pu Coated Outer Frame, Series DIT-E-W

Description:

Dynemech Anti Vibration Tables – Series DIT-E-W has a PU coated wooden outer frame. The Vibrations are isolated using Dp Insulation mounts. These Anti-Vibration Tables have a Granite Surface Plate with Grade-00/Grade-1 accuracy for very precise measuring accuracies. These Vibration Tables provide the most economical solution where high frequency vibrations need to be removed.

Applications:

The Vibration Isolated Table (VIT) finds usage in critical areas where reading accuracy of instruments like Balances, Galvanometers, Electronic Microscopes and Atomic Absorption Spectrophotometers, is affected by Vibration

Model Load (Kg) Length (mm) Width (mm)
DIT-E-W-01 upto 250 500 500
DIT-E-W-01-s1 upto 250 630 630
DIT-E-W-02 upto-450 750 500
DIT-E-W-03 upto-1250 900 600
DIT-E-W-04 upto-1250 1000 800

Series:

Anti Vibration Table With Elastomeric Isolation With Steel Cabinets And Supports-Granite Top, Series DIT-E-CDG

Description:

Dynemech Anti Vibration Tables – Series DIT-E-CDG has a sheet metal closed cabinet design. The Vibrations are isolated using Double-Layered Dp Elastomeric Sheets. These Anti-Vibration Tables have Granite Surface Plate with Grade-00/Grade-1 accuracy for very precise measuring accuracies. These Vibration Tables provide the most economical solution where high frequency vibrations need to be removed.

Applications:

The Vibration Isolated Table (VIT) finds usage in critical areas where reading accuracy of instruments like Balances, Galvanometers, Electronic Microscopes and Atomic Absorption Spectrophotometers, is affected by Vibrations

Model Load (Kg) Length (mm) Width (mm)
DIT-E-CDG-01 upto 250 500 500
DIT-E-CDG-01-S1 upto 250 630 630
DIT-E-CDG-02 upto 450 750 500
DIT-E-CDG-03 upto-1250 900 600
DIT-E-CDG-04 upto-1250 1000 800

Series:

Anti Vibration Table With Elastomeric Isolation With Steel Cabinets, Supports & Ss Top, Series DIT-E-CDSS

Description:

Dynemech Anti Vibration Tables – Series DIT-E-CDSS has a sheet metal closed cabinet design. The Vibrations are isolated using Double-Layered Dp Elastomeric Sheets. These Anti-Vibration Tables have Granite Surface Plate with Grade-00/Grade-1 accuracy for very precise measuring accuracies. These Vibration Tables provide the most economical solution where high frequency vibrations need to be removed.

Applications:

The Vibration Isolated Table (VIT) finds usage in critical areas where reading accuracy of instruments like Balances, Galvanometers, Electronic Microscopes and Atomic Absorption Spectrophotometers, is affected by Vibrations

Model Load (Kg) Length (mm) Width (mm)
DIT-E-CDSS-01 upto 250 500 500
DIT-E-CDSS-02 upto 250 630 630
DIT-E-CDSS-03 upto 450 750 500
DIT-E-CDSS-04 upto-1250 900 600
DIT-E-CDSS-05 upto-1250 1000 800
DIT-E-CDSS-06 upto-1250 1200 1000
DIT-E-CDSS-07 upto-1500 1800 1500

Series:

Anti Vibration Table, Elastomeric Isolation With Stainless Steel Table Frame, Series DIT-E-SFG

Description:

Dynemech Anti Vibration Tables – Series DIT-E-SFG are ideal for Testing / Quality Laboratories located in medical/food-grade industries as the table is having a stainless steel frame. The Vibrations are isolated using Double-Layered Dp Elastomeric Sheets. Granite Surface Plate with Grade-00/Grade-1 accuracy for very precise measuring accuracies. We can select up-to five layers of insulation plate depending upon the vibrations present in the Testing Laboratory. These Vibration Tables provide the most economical solution where high frequency vibrations need to be removed.

Applications:

The Vibration Isolated Table (VIT) finds usage in critical areas in medical and foodgrade industries where reading accuracy of instruments like Balances, Galvanometers, Electronic Microscopes and Atomic Absorption Spectrophotometers, is affected by Vibrations

Model Load (Kg) Length (mm) Width (mm)
DIT-E-SFG-01 upto 250 500 500
DIT-E-SFG-01-S1 upto 250 630 630
DIT-E-SFG-02 upto 450 750 500
DIT-E-SFG-03 upto-1250 900 600
DIT-E-SFG-04 upto-1250 1000 800

Series:

Anti Vibration Table, Elastomeric Isolation With Two Stage Levelling & Vibration Isolation, Series DIT-E-LDLM

Description:

Dynemech Anti Vibration Tables – Series DIT-E-LDLM is having a two stage levelling mechanism. The Vibrations are isolated using DLM mounts. These Anti-Vibration Tables have a Granite Surface Plate with Grade-00/Grade-1 accuracy for very precise measuring accuracies. These Vibration Tables provide the most economical solution where high frequency vibrations need to be removed. The passive vibrations from nearby motors and other heavy machinery is reduced by 65-70%.

Applications:

The Vibration Isolated Table (VIT) finds usage in critical areas where reading accuracy of instruments like Balances, Galvanometers, Electronic Microscopes and Atomic Absorption Spectrophotometers, is affected by Vibrations

Model Load (Kg) Length (mm) Width (mm)
DIT-E-LDLM-01 upto 250 500 500
DIT-E-LDLM-01-s1 upto 250 630 630
DIT-E-LDLM-02 upto-450 750 500
DIT-E-LDLM-03 upto-1250 900 600
DIT-E-LDLM-04 upto-1250 1000 800

Series:

Anti Vibration Table, Elastomeric Isolation With Two Stage Levelling & Vibration Isolation And Honeycomb Top, Series DIT-E-LDLM-HC

Description:

Dynemech Anti Vibration Tables – Series DITE-LDLM-HC is having a two stage levelling mechanism. The Vibrations are isolated using DLM mounts. These Anti-Vibration Tables have a Honeycomb Surface Plate with very precise measuring accuracies. These Vibration Tables provide the most economical solution where high frequency vibrations need to be removed. The passive vibrations from nearby motors and other heavy machinery is reduced by 65-70%.

Applications:

The Vibration Isolated Table (VIT) finds usage in critical areas where reading accuracy of instruments like Balances, Galvanometers, Electronic Microscopes and Atomic Absorption Spectrophotometers, is affected by Vibrations

Model Load (Kg) Length (mm) Width (mm)
DITE-LDLM-HC-01 upto 400 500 500
DITE-LDLM-HC-01-s1 upto 400 630 630
DITE-LDLM-HC-02 upto-850 750 500
DITE-LDLM-HC-03 upto-1150 900 600
DITE-LDLM-HC-04 upto-1250 1000 800
DITE-LDLM-HC-05 upto-1250 1200 1000
DITE-LDLM-HC-06 upto-1250 1500 900
DITE-LDLM-HC-07 upto-1250 1800 1200

Series:

Anti Vibration Table, Elastomeric Vibration Isolation With Granite Tabletop & Wrap Around Plate, Series DIT-E-WAG

Description:

Dynemech Anti Vibration Tables Series DITE-WAG are ideal for Testing / Quality Laboratories co-located with industrial units having high degree of vibration due to working machines like presses, hammers, VMCs etc. The Vibrations are isolated using Double-Layered Dp Elastomeric Sheets. The passive vibrations from nearby motors and other heavy machinery is reduced by 65-70%. The vibration isolation efficiency of these tables can be further increased by placing more than 2 layers of our Dp insulation Sheets. Five layers of DP exhibits a natural frequency of 7-8 Hz. which damps most of the incoming frequencies above 20 Hz.

Applications:

The Vibration Isolated Table (VIT) finds usage in critical areas where reading accuracy of instruments like Balances, Galvanometers, Electronic Microscopes and Atomic Absorption Spectrophotometers is affected by Vibrations

Model Load (Kg) Length (mm) Width (mm)
DIT-E-WAG-01 upto 250 500 500
DIT-E-WAG-01-S1 upto 250 630 630
DIT-E-WAG-02 upto-450 750 500
DIT-E-WAG-03 upto-1250 900 600
DIT-E-WAG-04 upto-1250 1000 800

Series:

Anti Vibration Table, Elastomeric Vibration Isolation With Granite Tabletop & Top Storage, Series DIT-E-GSR

Description:

Model Load (Kg) Length (mm) Width (mm)
DIT-E-GSR-01-757590 upto 700 750 750
DIT-E-GSR-02-906090 upto 800 900 600
DIT-E-GSR-03-909090 upto 1000 900 900
DIT-E-GSR-04-12010090 upto-1000 1200 1000
DIT-E-GSR-05-12012090 upto-1000 1200 1200
DIT-E-GSR-06-18012090 upto-1000 1800 1200
DIT-E-GSR-07-24012090 upto-1200 2400 1200

Series:

Anti Vibration Table, Elastomeric Vibration Isolation With Granite Isolated Payload Area In Wooden Table Top Frame, Series DIT-E-GPW

Description:

Dynemech anti-vibration table series DIT-E-GPW is suitable for all types of measuring and testing equipment used in the labs and clean rooms. The body of the table is made from low carbon steel powder coated outer frame provide sturdiness to the structure of the table. The natural frequency of this table is in the range of 1-1.5 Hz which damps out most of the vibrations above 3 Hz. Available self-levelling accuracy options are +/- 0.010 and +/- 0.10 with minimum setting time, depending upon the application requirement. These tables have a levelling adjustable leg. The first stage levelling is done by rotating the nut, the level of the granite top can be maintained using precision spirit level/electronic level gauge. The top is made from a heavy granite slab which ensures rigidity and keeps the system stable and ensures lower natural frequency and high damping efficiency. The flatness accuracy of these granites is of grade ‘0’ or ‘00’ depending upon the application. The top surface of the granite slab is velvet finish to ensure smooth and lustrous finish. The frame of the table is made from the structural steel having grade IS 2062.Monitor stand, drawers, CPU space is provided as per the customer’s requirement. The body of the table is Powder coated to achieve corrosion free service life of the table. Optional sturdy castor wheels are also provided for heavy versions for easy relocation of the table. Keyboard, CPU and monitor stands, Drawers and cabinets can also be accommodated in these tables as per the application requirements. The vibration isolation is achieved at 2 stages. The first stage is in the legs where the anti-vibration pads are assembled in the levelling leg which damps medium to high frequency vibrations. The second level of vibration isolation is achieved by the membrane air springs which isolates a wide low to high frequency range of the incoming vibrations. The isolated area is separated from the outer area and is supported in dependently from the ground. Any disturbance to the outer area will not affect the readings in the isolated area. Optional sturdy castor wheels are also provided for heavy versions for easy relocation of the table. Keyboard, CPU and monitor stands,. Drawers and cabinets can also be accommodated in these tables as per the application requirements. Optional sturdy castor wheels are also provided for heavy versions for easy relocation of the table. These tables undergo a modern manufacturing process and rigorous testing before being supplied to customers. The entire process is carried out in our dedicated in-house facility.

Applications:

The Vibration Isolated Table (VIT) finds usage in critical areas where reading accuracy of instruments like Balances, Galvanometers, Electronic Microscopes and Atomic Absorption Spectrophotometers, is affected by vibrations ; In Laboratories and Research Facilities for accurate chemical analysis, food sample testing, sensitive scientific research , in pharmaceuticals, food and beverage & chemical industries; in Semiconductor Manufacturing and R&D ; in Weighing Experiments and Scientific Analysis

Model Load (Kg) Length (mm) Width (mm)
DIT-E-GPW-01 upto 400 500 500
DIT-E-GPW-01-s1 upto 400 630 630
DIT-E-GPW-02 upto 850 750 500
DIT-E-GPW-03 upto-1150 900 600
DIT-E-GPW-04 upto-1250 1000 800
DIT-E-GPW-05 upto-1250 1200 1000
DIT-E-GPW-06 upto-1500 1800 1500

Series:

Anti Vibration Table, Elastomeric Vibration Isolation With Granite Isolated Payload Area In Granite Table Top, Series DIT-E-GPG

Description:

Dynemech Anti-Vibration Table Series DITE-E-GPG is suitable for all types of measuring and testing equipment used in the labs and clean rooms. These tables have a levelling adjustable leg. By rotating the nut, the level of the granite top can be maintained using precision spirit level/electronic level gauge. The top is made from a heavy granite slab which ensures rigidity and keeps the system stable and ensures lower natural frequency and high damping efficiency. The flatness accuracy of these granites is of grade ‘0’ or ‘00’ depending upon the application. The top surface of the granite slab is velvet finish to ensure smooth and lustrous finish. The frame of the table is made from the structural steel having grade IS 2062. Powder coating on the frame is done to maintain corrosion free service life of the table. The vibration isolation is achieved at 2 stages. The first stage is in the legs where the anti-vibration pads are assembled in the levelling leg which damps medium to high frequency vibrations. The second level of vibration isolation is achieved by DP1 layer of special profiled vibration insulation plates. This stack of the vibration insulation plate is tuned to low natural frequency and damps most of the incoming vibrations above 15-20 Hz. The isolated area is separated from the outer area and is supported in dependently from the ground. Any disturbance to the outer area will not affect the readings in the isolated area. Optional sturdy castor wheels are also provided for heavy versions for easy relocation of the table. Keyboard, CPU and monitor stands,. Drawers and cabinets can also be accommodated in these tables as per the application requirements. These tables undergo a modern manufacturing process and rigorous testing before being supplied to customers. The entire process is carried out in our dedicated inhouse facility.

Model Load (Kg) Length (mm) Width (mm)
DIT-E-GPG-01 upto 250 500 500
DIT-E-GPG-01-s1 upto 250 630 630
DIT-E-GPG-02 upto-450 750 500
DIT-E-GPG-03 upto-1250 900 600
DIT-E-GPG-04 upto-1250 1000 800
DIT-E-GPG-05 upto-1250 1200 1000
DIT-E-GPG-06 upto-1500 1800 1500

Series:

Anti Vibration Table, Elastomeric Vibration Isolation With 2 Stage Payload Area Isolated Table, Series DIT-E-PALM

Description:

Model Load (Kg) Length (mm) Width (mm)
DIT-E-PALM-01 upto 250 500 500
DIT-E-PALM-01-s1 upto 250 630 630
DIT-E-PALM-02 upto-450 750 500
DIT-E-PALM-03 upto-1250 900 600
DIT-E-PALM-04 upto-1250 1000 800
DIT-E-PALM-05 upto-1250 1200 1000
DIT-E-PALM-06 upto-1500 1800 1500